vLED indicators to report errors that occur with fans, power supplies, microprocessor, hard disk drives, and system errors (EasyLED Diagnostics)
vDIMM error assistance. The Unified Extensible Firmware Interface (UEFI) will disable a failing DIMM that is detected during POST IMM will light the associated system error LED and the failing DIMM error LED.
vSystem event log (SEL)
v
vAuto Boot Failure Recovery (ABR)
vA virtual media key which enables full system management support (remote video, remote keyboard/mouse, and remote storage)
vAutomatic microprocessor disable on failure restart in a
vNMI detection and reporting
vSMI handling
vAutomatic Server Restart (ASR) when (1) POST is not complete or (2) the OS hangs and the OS Watchdog Timer
vIntelligent Platform Management Interface (IPMI) Specification V2.0 and Intelligent Platform Management Bus (IPMB) support
vInvalid system configuration (CNFG) LED support
vSerial redirect
vSerial Over LAN (SOL)
vActive Energy Manager
vQuery power supply input power
vPECI 2 support
vPower/Reset control
vAlerts
vOperating system failure blue screen capture
vCommand line interface
vConfiguration save and restore
vPCI configuration data
vBoot sequence manipulation
The IMM also provides the following remote server management capabilities:
vCommand-line interface (IPMI Shell)
The
vSerial over LAN
Establish a Serial over LAN (SOL) connection to manage servers from a remote location. You can remotely view and change the UEFI settings, restart the server, identify the server, and perform other management functions. Any standard Telnet client application can access the SOL connection.
120ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Installation and User Guide