Table 15. EasyLED panel LEDs (continued)

LED

Description

Action

 

 

 

 

CPU

A microprocessor has

1.

Make sure that the failing microprocessor,

 

failed.

 

 

which is indicated by a lit LED on the

 

 

 

 

 

 

system board, is install correctly.

 

 

2.

(Trained service technician only) Replace

 

 

 

the microprocessor.

 

 

 

 

DASD

A hard disk drive error has

1.

Check the LEDs on the hard disk drives and

 

occurred.

 

replace the hard disk drive with the lit LED.

 

 

 

 

 

2.

Replace the hard disk drive backplane.

 

 

 

 

RAID

A RAID controller error

1.

Make sure that a RAID controller is installed

 

has occurred.

 

 

correctly.

 

 

 

 

 

2.

Check the system-error log for information

 

 

 

about the error.

 

 

 

 

BRD

An error has occurred on

1.

Check the LEDs on the system board to

 

the system board.

 

 

identify the component that caused the error.

 

 

 

 

 

2.

Check the system-error log for information

 

 

 

about the error.

 

 

 

 

Power-supply diagnostics

The following illustration shows the power-supply LEDs on the rear of the server. For more information about solving power-supply problems, see the Hardware Maintenance Manual.

1 AC power LED (green) 2 DC power LED (green)

3 Power-supply error LED (amber)

The following table describes the problems that are indicated by various combinations of the power-supply LEDs and the power-on LED on the operator information panel and suggested actions to correct the detected problems.

148ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Installation and User Guide