1 | Cover | 11 | CD/DVD drive |
2 | PCI | 12 | Operator information panel |
3 | PCI | 13 Front bezel (some models) | |
4 | Heat sink | 14 | |
5 | Microprocessor | 15 SAS hard disk drive backplanes | |
6 | 16 | SAS riser card | |
7 | DIMM | 17 | Fan bracket |
8 | System board | 18 | Fans |
9 | 19 | DIMM air baffle | |
10 | Power supply | 20 Microprocessor 2 air baffle |
Removing the cover
Important: Before you install optional hardware, make sure that the server is working correctly. Start the server, and make sure that the operating system starts, if an operating system is installed, or that a 19990305 error code is displayed, indicating that an operating system was not found but the server is otherwise working correctly. If the server is not working correctly, see the Hardware Maintenance Manual for diagnostic information.
To remove the cover, complete the following steps:
1.Read the safety information that begins on page vii and “Installation guidelines” on page 33.
2.If you are planning to view the error LEDs that are on the system board and components, leave the server connected to power and go directly to step 4 on page 38.
3.If you are planning to install or remove a microprocessor, memory module, PCI adapter, battery, or other
Chapter 5. Installing optional devices and replacing customer replaceable units 37