Table 10.
| Number of installed |
|
DIMMs | microprocessors | DIMM connector |
|
|
|
First pair of DIMMs | 1 | 3, 6 |
|
|
|
Second pair of DIMMs | 1 | 2, 5 |
|
|
|
Third pair of DIMMs | 1 | 1, 4 |
|
|
|
Fourth pair of DIMMs | 2 | 14, 11 |
|
|
|
Fifth pair of DIMMs | 2 | 13, 10 |
|
|
|
Sixth pair of DIMMs | 2 | 12, 9 |
|
|
|
Note: DIMM connectors 7, 8, 15, and 16 are not used in
When you install or remove DIMMs, the server configuration information changes. When you restart the server, the system displays a message that indicates that the memory configuration has changed.
Installing a DIMM
To install a DIMM, complete the following steps.
1.Read the safety information that begins on page vii and “Installation guidelines” on page 33.
2.Turn off the server and peripheral devices, and disconnect the power cord and all external cables (see “Turning off the server” on page 31).
3.Remove the server cover (see “Removing the cover” on page 37).
1 DIMM air baffle
2 PCI
68ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Installation and User Guide