LG Electronics C Series manual How to monitor fault condition in Drive group

Models: C Series

1 127
Download 127 pages 40.51 Kb
Page 36
Image 36

Chapter 5. Programming keypad

How to monitor fault condition in Drive group

Over-

During

current

Accel

 

trip

Current

 

 

Frequency

Drive group

STOP/RST

1

2

3

4

-. This message appears when an Overcurrent fault occurs. -. Press the Prog/Ent (z) key once.

-. The run frequency at the time of fault (30.0) is displayed. -. Press the Up (S) key once.

-. The output current at the time of fault is displayed. -. Press the Up (S) key once.

-. Operating status is displayed. A fault occurred during acceleration. -. Press the STOP/RST key once.

5

-. A fault condition is cleared and “nOn” is displayed.

When more than one fault occur at the same time,

Motor overheating

Over voltage

Over current

-. Maximum three faults information is displayed as shown left.

Drive group

36