Chapter 7. Function list
1) Set H10 to 1 to be displayed.
# H17, 18 is used when F2, F3 is set to 1
Function group 2
| LED |
|
| Parameter |
|
| Min/Max |
|
|
|
|
|
|
|
|
| Description |
|
|
|
|
|
| Factory |
|
| Adjustable |
|
| Page |
|
| |||
| display |
|
| name |
|
| range |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| defaults |
|
| during run |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| H22 |
| [Speed | 0/15 |
|
| | This parameter is active to prevent any |
| 0 |
|
| O | 10- |
|
| |||||||||||||||||||
| 2) |
| Search |
|
|
|
| possible fault when the inverter outputs its |
|
|
|
|
|
|
| 12 |
|
| |||||||||||||||||
|
|
| Select] |
|
|
|
| voltage to the running motor. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 1. H20- |
| 2.Restart |
| 3.Operation |
| 4.Normal |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| [Power |
| after |
| after fault |
| acceler- |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| On start] |
| instant |
| occurred |
|
| ation |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| power |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| failure |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Bit 3 |
| Bit 2 |
| Bit 1 |
|
| Bit 0 |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 0 |
|
|
| - |
| - |
| - |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 1 |
|
|
| - |
| - |
| - |
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 2 |
|
|
| - |
| - |
| 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 3 |
|
|
| - |
| - |
| 3 |
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 4 |
|
|
| - |
| 3 |
| - |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 5 |
|
|
| - |
| 3 |
| - |
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 6 |
|
|
| - |
| 3 |
| 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 7 |
|
|
| - |
| 3 |
| 3 |
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 8 |
|
|
| 3 |
| - |
| - |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 9 |
|
|
| 3 |
| - |
| - |
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 10 |
|
|
| 3 |
| - |
| 3 |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 11 |
|
|
| 3 |
| - |
| 3 |
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 12 |
|
|
| 3 |
| 3 |
| - |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 13 |
|
|
| 3 |
| 3 |
| - |
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 14 |
|
|
| 3 |
| 3 |
| 3 |
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 15 |
|
|
| 3 |
| 3 |
| 3 |
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
| H23 | [Current level | 80/200 |
|
| | This |
| parameter limits the amount of |
| 100 |
|
| O | 10- |
|
| ||||||||||||||||||
|
|
| during Speed | [%] |
|
|
|
| current during speed search. |
|
|
|
|
|
|
|
|
|
|
| 12 |
|
| ||||||||||||
|
|
| search] |
|
|
|
| | The | set value is the percentage of the |
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| H33- [Motor rated current]. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| H24 | [P gain during | 0/9999 |
|
| | It is the Proportional gain used for Speed |
| 100 |
|
| O |
|
|
|
| |||||||||||||||||||
|
|
| Speed |
|
|
|
|
|
| Search PI controller. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
| search] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| H25 | [I gain during | 0/9999 |
|
| | It is | the Integral gain used for |
| Speed |
| 1000 |
|
| O |
|
|
|
| ||||||||||||||||
|
|
| speed |
|
|
|
|
|
| search PI controller. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
| search] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 2) #4.Normal acceleration has first priority. Even though #4 is selected along with other bits, Inverter starts Speed search #4. |
|
|
|
| ||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Function group 2 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| LED |
|
| Parameter |
|
| Min/Max |
|
|
|
|
|
| Description |
|
|
|
| Factory |
|
| Adjustable |
|
| Page |
|
| ||||||||
| display |
|
| Name |
|
| Range |
|
|
|
|
|
|
|
|
|
| defaults |
|
| during run |
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| H26 |
| [Number of | 0/10 |
|
| |
| This parameter sets the number | of |
|
| 0 |
|
| O | 10- |
|
| ||||||||||||||||
|
|
| Auto Restart |
|
|
|
|
|
| restart tries after a fault occurs. |
|
|
|
|
|
|
|
|
|
|
| 15 |
|
| |||||||||||
|
|
| try] |
|
|
|
| |
| Auto Restart is deactivated if the fault |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| outnumbers the restart tries. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| | This function is active when [drv] | is |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| set to 1 or 2 {Run/Stop via control |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| terminal}. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| | Deactivated | during | active protection |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| function (OHT, LVT, EXT, HWT etc.) |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
| H27 |
| [Auto Restart |
| 0/60 [sec] | |
| This parameter sets the time between |
| 1.0 |
|
| O |
|
|
|
| ||||||||||||||||||
|
|
| time] |
|
|
|
| restart tries. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| H30 |
| [Motor type | 0.2/2.2 |
|
| 0.2 |
|
|
|
| 0.2 kW |
|
|
|
|
|
|
| 1) |
|
| X |
|
| ||||||||||
|
|
| select] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| 0.4 |
|
|
|
| 0.4 kW |
|
|
|
|
|
| Automatically |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| 0.75 |
|
|
| 0.75 kW |
|
|
|
|
|
|
|
|
| set |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 1.5 |
|
|
|
| 1.5 kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 2.2 |
|
|
|
| 2.2 kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
48