10. Advanced functions
2nd motor operation does not run 2 motors at the same time. As the figure below, when using two motors with an inverter by exchanging them, different values can be set for the 2nd motor via the
Turn the I24 (setting: 12) On after motor is stopped.
Parameters from H81 to H90 are applied to the 1st motor as well as the 2nd motor.
SV-iC5
C series
P5
Motor 1
Motor 2
10.15 Parameter initialize & Lock
zParameter initialize
Group | LED | Parameter Name |
| Min/Max |
| Factory |
Display |
| Range |
| Default | ||
|
|
|
| |||
Function | H93 | [Parameter initialize] | 0 | - |
| 0 |
group 2 |
| |||||
|
|
|
|
|
| |
|
| 1 | Initialize all 4 | parameter |
| |
|
|
|
| |||
|
|
| groups |
|
| |
|
|
|
|
|
| |
|
|
| 2 | Initialize Drive group Only |
| |
|
|
|
|
|
| |
|
|
| 3 | Initialize Function group 1 |
| |
|
|
| Only |
|
| |
|
|
|
|
|
| |
|
|
| 4 | Initialize Function group 2 |
| |
|
|
| Only |
|
| |
|
|
|
|
|
| |
|
|
| 5 | Initialize I/O group Only |
| |
|
|
|
|
|
|
|
Select the group to be initialized and initialize the parameters in H93.
Press the Prog/Ent (z) key after selecting the desired number in H93. H93 will reappear after the setting.
96