Chapter 7. Function list
Function group 2
| LED | Parameter | Min/Max |
|
|
|
|
| Description |
|
| Factory | Adjustable |
| Page |
|
| display | Name | Range |
|
|
|
|
|
|
| defaults | during run |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||||
| H51 | [P gain for | 0/999.9 | |
| This parameter sets the gains for the |
| 300.0 | O |
| ||||||
|
| PID controller] | [%] |
|
| PID controller. |
|
|
|
|
|
| ||||
| H52 | [Integral time | 0.1/32.0 |
|
|
|
|
|
|
| 1.0 | O |
| |||
|
| for PID | [sec] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| controller |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (I gain)] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| H53 | Differential | 0.0 /30.0 |
|
|
|
|
|
|
| 0.0 | O |
| |||
|
| time for PID | [sec] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| controller |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (D gain) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| H54 | F gain for PID | 0/999.9 | |
| This is the Feed forward gain for the PID | 0.0 | O |
| |||||||
|
| controller | [%] |
|
| controller. |
|
|
|
|
|
| ||||
| H55 | [PID output | 0/400 | |
| This parameter limits the amount of the | 60.0 | O |
| |||||||
|
| frequency | [Hz] |
|
| output frequency thru the PID control. |
|
|
|
|
|
| ||||
|
| limit] |
| |
| The value is settable within the range of |
|
|
|
|
|
| ||||
|
|
|
|
|
| F21 – [Max frequency] and H23 – [Start |
|
|
|
|
|
| ||||
|
|
|
|
|
| frequency]. |
|
|
|
|
|
| ||||
| H70 | [Frequency | 0/1 | 0 |
|
|
| The Accel/Decel time is the time that | 0 | X |
| |||||
|
| Reference for |
|
|
|
|
|
| takes to reach the F21 – [Max |
|
|
|
|
|
| |
|
| Accel/Decel] |
|
|
|
|
|
| frequency] from 0 Hz. |
|
|
|
|
|
| |
|
|
|
| 1 |
|
|
| The Accel/Decel time is the time that |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| takes to reach a target frequency |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| from the run frequency. |
|
|
|
|
|
| |
| H71 | [Accel/Decel | 0/2 | 0 |
|
|
| Unit: 0.01 second. | 1 | O |
| |||||
|
| time scale] |
| 1 |
|
|
| Unit: 0.1 second. |
|
|
|
|
|
| ||
|
|
|
| 2 |
|
|
| Unit: 1 second. |
|
|
|
|
|
| ||
| H72 | [Power on | 0/13 | |
| This | parameter selects the parameter to | 0 | O |
| ||||||
|
| display] |
|
|
| be displayed on the keypad when the input |
|
|
|
|
|
| ||||
|
|
|
|
|
| power is first applied. |
|
|
|
|
|
| ||||
|
|
|
| 0 |
|
|
| Frequency command |
|
|
|
|
|
| ||
|
|
|
| 1 |
|
|
| Accel time |
|
|
|
|
|
| ||
|
|
|
| 2 |
|
|
| Decel time |
|
|
|
|
|
| ||
|
|
|
| 3 |
|
|
| Drive mode |
|
|
|
|
|
| ||
|
|
|
| 4 |
|
|
| Frequency mode |
|
|
|
|
|
| ||
|
|
|
| 5 |
|
|
|
|
|
|
|
|
| |||
|
|
|
| 6 |
|
|
|
|
|
|
|
|
| |||
|
|
|
| 7 |
|
|
|
|
|
|
|
|
| |||
|
|
|
| 8 |
|
|
| Output current |
|
|
|
|
|
| ||
|
|
|
| 9 |
|
|
| Motor rpm |
|
|
|
|
|
| ||
|
|
|
| 10 |
|
| Inverter DC link voltage |
|
|
|
|
|
| |||
|
|
|
| 11 |
|
| User display select |
|
|
|
|
|
| |||
|
|
|
| 12 |
|
| Fault display |
|
|
|
|
|
| |||
|
|
|
| 13 |
|
| Direction of motor rotation select |
|
|
|
|
|
| |||
| H73 | [Monitoring | 0/2 | |
| One | of the following can be monitored | 0 | O |
| ||||||
|
| item select] |
|
|
| via vOL - [User display select]. |
|
|
|
|
|
| ||||
|
|
|
| 0 |
|
| Output voltage [V] |
|
|
|
|
|
| |||
|
|
|
| 1 |
|
| Output power [kW] |
|
|
|
|
|
| |||
|
|
|
| 2 |
|
| Torque [kgf ⋅ m] |
|
|
|
|
|
| |||
| H74 | [Gain for | 1/1000 | |
| This parameter is used to change the | 100 | O |
| |||||||
|
| Motor rpm | [%] |
|
| motor speed display to rotating speed |
|
|
|
|
|
| ||||
|
| display] |
|
|
| (r/min) or mechanical speed (m/mi). |
|
|
|
|
|
|
|
|
| ⎛ 120 ⋅ f | ⎞ |
| H 74 |
|
|
| ||
|
|
| RPM = ⎜ |
| ⎟ | ⋅ |
|
|
|
|
|
|
|
| H 31 | 100 |
|
|
|
| |||
|
|
| ⎝ | ⎠ |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||||
H79 | [Software | 0/10.0 | This parameter displays the inverter | X.X | X |
| |||||
| version] |
| software version. |
|
|
|
|
|
|
|
|
H81 | [2nd motor | 0/6000 | This parameter is active when the | 5.0 | O | 10- | |||||
| Accel time] | [sec] | selected terminal is ON after |
|
| 16 | |||||
|
|
| d |
|
|
|
|
|
|
|
|
50