Chapter 9. Basic functions
zAnalog Frequency setting via Potentiometer (V0) on the Keypad Used to prevent fluctuations in analog input signals caused by noise.
|
| Group |
|
| LED Display |
|
| Parameter Name |
|
| Set |
|
|
| Min/Max |
|
| Factory |
|
| Unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| Value |
|
|
| Range |
|
| Defaults |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Drive | 0.0 |
|
| [Frequency Command] | - |
| - |
| - |
|
| Hz | |||||||||
| group |
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Frq |
|
| [Frequency Mode] |
|
| 2 |
| 0/8 |
| 0 |
|
|
|
| |||
| I/O |
| I 1 |
| [Filter time constant for V0 | 10 |
| 0/9999 |
| 10 |
|
|
|
| ||||||||
| group |
|
| input] |
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
| I 2 |
| [V0 input minimum voltage] | - |
| 0/10 |
| 0 |
|
| V | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| I 3 |
| [Frequency corresponding to | - |
| 0/400 |
| 0.0 |
|
| Hz | |||||||
|
|
|
|
|
| I2] |
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| I 4 |
| [V0 input max voltage] | - |
| 0/10 |
| 10 |
|
| V | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| I 5 |
| [Frequency corresponding to | - |
| 0/400 |
| 60.0 |
|
| Hz | |||||||
|
|
|
|
|
| I4] |
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Set Frq – [Frequency Mode] to 2.
The set frequency can be monitored in 0.0- [Frequency Command].
I 1: [Filtering time constant for V0 input]
Effective for eliminating noise in the frequency setting circuit.
Increase the filter time constant if steady operation cannot be performed due to noise. A larger setting results in slower response (t gets longer).
V0 input
Set freq
t
I 2 - I 5: [Min/Max input voltage and corresponding frequency setting]
The corresponding frequency to V0 input voltage is settable.
Example: When setting I 2 - [V0 input minimum voltage] = 2V, I 3- [Frequency corresponding to I 2] = 10Hz, I 4 - [V0 input max voltage] = 8V and I 5 - [Frequency corresponding to I 4] = 50Hz, the following figure is shown.
Freq. |
|
|
|
setting | 50Hz |
|
|
I 5 |
|
|
|
I 3 | 10Hz |
|
|
| 2V | 8V | V0 input |
| I 2 | I 4 |
|