![](/images/new-backgrounds/1098743/98743119x1.webp)
Chapter 9. Basic functions
CHAPTER 9 - | Basic Functions |
9.1Frequency mode
zDigital Frequency setting via Keypad 1
| Group |
|
| LED Display |
|
| Parameter Name |
|
| Set |
|
| Min/Max |
|
| Factory |
|
| Unit |
|
|
|
|
|
|
|
| Value |
|
| Range |
|
| Defaults |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Drive | 0.0 |
|
| [Frequency Command] | - |
| 0/400 |
| 0.0 |
|
| Hz | ||||||||
group |
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| Frq |
|
| [Frequency mode] |
|
| 0 |
| 0/8 |
| 0 |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Run frequency is settable in 0.0 - [Frequency Command].
Set Frq – [Frequency mode] to 0 {Frequency setting via Keypad 1}.
Set the desired frequency in 0.0 and press the Prog/Ent (z) key to enter the value into memory.
The value is settable not greater than F21 – [Max frequency].
zDigital Frequency setting via Keypad 2
Group | LED Display | Parameter Name | Set | Min/Max | Factory | Unit | |
Value | Range | Defaults | |||||
|
|
|
|
Drive | 0.0 |
| [Frequency Command] | - |
| 0/400 | 0.0 | Hz | |||
group |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
| Frq |
| [Frequency mode] |
|
| 1 |
| 0/8 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Run frequency is settable in 0.0 - [Frequency Command].
Set Frq – [Frequency mode] to 1{Frequency setting via Keypad 2}.
In 0.0, frequency is changed upon pressing the Up (S)/Down (T) key. It is selected to use the Up/Down key as potentiometer on keypad.
The value is settable not greater than F21 – [Max frequency].
60