LG Electronics C Series manual Default Group I53 Frequency Detection 400 10.0 Bandwidth

Models: C Series

1 127
Download 127 pages 40.51 Kb
Page 106
Image 106

Chapter 11. Monitoring

I56: When 17 {Fault display} is selected in I54 and I55, Multi-function output terminal and relay will be activated with the value set in I56.

0: FDT-1

Check whether the output frequency of the inverter matches the user-setting frequency. Active condition: Absolute value (preset frequency - output frequency) <= Frequency Detection Bandwidth/2

 

Group

 

 

LED

 

 

Parameter Name

 

 

Set

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

 

 

Display

 

 

 

 

value

 

 

range

 

 

default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I/O group

 

I53

 

 

[Frequency Detection

 

 

-

 

0/400

 

10.0

 

 

Hz

 

 

 

 

 

 

Bandwidth]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒ Cannot be set above Max frequency (F21).

 

 

When setting I53 to 10.0

 

40Hz

 

20Hz

 

Freq.

 

 

 

setting

40Hz

 

 

 

 

35Hz

 

15Hz

20Hz

 

 

 

Freq.

 

 

MO

 

 

Run

 

 

command

 

1: FDT-2

It activates when the preset frequency matches frequency detection level (I52) and FDT-1 condition is met.

Active condition: (Preset frequency = FDT level) & FDT-1

Group

LED

Parameter Name

Set

Min/Max

Factory

Unit

Display

value

range

default

 

 

 

I/O group

 

I52

 

[Frequency

Detection

 

-

 

 

30.0

 

 

 

 

 

Level]

 

 

 

0/400

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

I53

 

[Frequency

detection

 

-

 

10.0

 

 

 

 

 

 

 

 

 

 

 

 

bandwidth]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒIt cannot be set above F21- [Max frequency].

When setting I52 and I53 to 30.0 Hz and 10.0 Hz, respectively

50Hz

Freq.30Hz setting

25Hz

Freq.

MO

Run command

106

Page 106
Image 106
LG Electronics C Series manual Default Group I53 Frequency Detection 400 10.0 Bandwidth, Parameter Name Set