Chapter 11. Monitoring

zUser display select

 

Group

 

 

LED

 

 

Parameter Name

 

 

Set

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

 

 

Display

 

 

 

 

value

 

 

range

 

 

default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

 

vOL

 

 

[User display select]

 

 

-

 

 

 

 

 

 

 

 

 

 

group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

H73

[Monitoring item select]

-

 

0/2

 

0

 

 

 

 

group 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒThe selected item in H73- [Monitoring item select] can be monitored in vOL- [User display select].

H73: Select one of the desired item numbers.

H73

[Monitoring

0

Output voltage [V]

 

 

item select]

 

 

 

 

 

 

 

 

 

 

 

 

1

Output power [kW]

 

 

 

 

 

 

 

 

2

Torque

 

 

 

 

 

 

Enter motor efficiency indicated on motor nameplate to H36 to display correct torque

zPower on display

 

Group

 

 

LED

 

 

Parameter Name

 

 

 

 

Setting

 

 

Factory

 

 

 

 

display

 

 

 

 

 

 

 

 

default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

H72

 

 

[Power on display]

 

 

0

 

Frequency command (0.0)

0

 

group 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Accel time (ACC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Decel time (DEC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Drive mode (drv)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

Frequency mode (Frq)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Multi-step frequency 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Multi-step frequency 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

`

 

 

7

 

Multi-step frequency 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

Output current (CUr)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

Motor rpm (rPM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

Inverter DC link voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(dCL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

User display select (vOL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

Fault display 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

Fault display 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒSelect the parameter to be displayed on the keypad when the input power is first applied.

101