LG Electronics C Series manual Frequency Setting via Analog Current Input 0-20mA

Models: C Series

1 127
Download 127 pages 40.51 Kb
Page 62
Image 62

Chapter 9. Basic functions

zAnalog Frequency setting via Voltage analog input (0-10V) or potentiometer on the VR terminal

 

 

Group

 

 

LED Display

 

 

Parameter Name

 

 

Set

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Value

 

 

Range

 

 

Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

0.0

 

 

[Frequency command]

-

 

-

 

-

 

 

Hz

 

group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frq

 

 

[Frequency mode]

 

 

3

 

0/8

 

0

 

 

 

 

 

I/O

 

I 6

 

[Filtering time constant for V1

10

 

0/9999

 

10

 

 

 

 

 

group

 

 

input]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I 7

 

[V1 input minimum voltage]

-

 

0/10

 

0

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I 8

 

[Frequency corresponding to I 7]

-

 

0/400

 

0.0

 

 

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I 9

 

[V1 input max voltage]

-

 

0/10

 

10

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I10

 

[Frequency corresponding to I 9]

-

 

0/400

 

60.0

 

 

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒSelect Frq -[Frequency Mode] to 3 {Frequency setting via V1 terminal}.

ƒThe 0-10V input can be directly applied from an external controller or a potentiometer (between VR and CM terminals).

Wire the terminal as shown below and refer to page 9-2 for I 6 - I10.

VR

V1

CM

When connecting potentiometer to

terminals VR and CM

V1

CM

Analog Voltage Input (0-10V)

zFrequency Setting via Analog Current Input (0-20mA)

Group

LED Display

Parameter Name

Set

Min/Max

Factory

Unit

Value

Range

Defaults

 

 

 

 

Drive

0.0

 

 

[Frequency Command]

-

 

-

-

Hz

group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frq

 

 

[Frequency Mode]

 

 

4

 

0/8

0

 

I/O

 

I11

 

[Filtering time constant for I input]

10

 

0/9999

10

 

group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I12

 

[I input minimum current]

-

 

0/20

4

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I13

 

[Frequency corresponding to I 12]

-

 

0/400

0.0

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I14

 

[I input max current]

-

 

0/20

20

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I15

 

[Frequency corresponding to I 14]

-

 

0/400

60.0

Hz

ƒSelect Frq – [Frequency Mode] to 4 {Current Analog Input (0-20mA)}.

ƒFrequency is set via 0-20mA input between I and CM terminals.

62

Page 62
Image 62
LG Electronics C Series manual Frequency Setting via Analog Current Input 0-20mA