Chapter 10. Advanced functions

zStarting DC brake

 

Group

 

 

LED Display

 

 

Parameter Name

 

 

Set

 

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

 

 

 

 

 

 

value

 

 

 

Range

 

 

Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

F12

 

 

[DC Brake start voltage]

 

 

-

 

0/200

 

50

 

%

 

group 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F13

 

 

[DC Brake start time]

 

 

-

 

0/60

 

0

 

 

sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒF12: It sets the level as a percent of H33 – [Motor rated current].

ƒF13: Motor accelerates after DC voltage is applied for the set time.

CAUTION:

If excessive DC Brake voltage is set or DC Brake time is set too long, it may cause motor overheating and damage to the motor.

Freq.

 

F13

t

Voltage

F12

Run

 

command

 

Setting F12 or F13 to 0 will disable Starting DC brake.

t:After F13 - [DC Brake start time], the frequency is increasing after DC voltage is applied until the time t. In this case, DC Brake start time may be longer than the set value.

zDC brake at a stop

 

Group

 

 

LED Display

 

 

Parameter Name

 

 

Set

 

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

 

 

 

 

 

 

value

 

 

 

Range

 

 

Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

F12

 

 

[DC Brake start voltage]

 

 

-

 

0/200

 

50

 

%

 

group 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I/O

 

I22

 

 

[Multi-function

input

 

 

11

 

0/24

 

2

 

 

 

 

group

 

 

 

terminal P3 define]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒF12: Set as a percent of H33 – [Motor rated current].

ƒSelect a terminal to issue a command of DC brake during stop among P1 thru P5.

ƒIf P3 terminal is set for this function, set 22 to 11 {DC brake during stop}.

￿Caution:

If excessive DC Brake voltage is set or DC Brake time is set too long, it may cause motor overheating and damage to the motor.

Voltage

P3 Run

command

F12

80

Page 80
Image 80
LG Electronics C Series manual Voltage P3 Run Command F12