Chapter 12. Protective functions

Current

Freq.

Multi-functi on output or relay

During acceleration

F60

t1

t2

During constant run

DC voltage

Freq.

Multi-function output or relay

During deceleration

12.4 Output phase loss protection

Group

Function group 2

 

 

 

 

 

 

 

LED

 

 

Parameter Name

 

 

display

 

 

 

 

 

 

 

 

 

H19

 

 

[Output phase loss

 

 

 

protection select]

 

 

 

 

Set value

1

 

 

 

 

 

 

 

 

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

setting

 

 

default

 

 

 

 

 

 

 

 

 

 

0/1

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒSet H19 value to 1.

ƒThis function turns off the inverter output in the event of more than one phase loss among U, V and W output.

CAUTION :

Set H33- [Motor rated current] correctly. If the actual motor rated current and the value of H33 are different, this function could not be activated.

113

Page 113
Image 113
LG Electronics C Series manual Freq, Output phase loss protection