Chapter 7. Function list
Function group 1
| LED | Parameter |
| Min/Max |
|
|
| Description |
| Factory |
| Adjustable |
| Page |
| ||
| display | name |
| range |
|
|
|
| defaults |
| during run |
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||||||
| F 0 | [Jump code] |
| 0/60 |
| This parameter sets the parameter code | 1 |
| O |
| |||||||
|
|
|
|
|
|
| number to jump. |
|
|
|
|
|
|
| |||
| F 1 | [Forward/ | 0/2 | 0 |
| Fwd and rev run enable | 0 |
| X |
| |||||||
|
|
| Reverse run |
|
| 1 |
| Forward run disable |
|
|
|
|
|
|
| ||
|
|
| disable] |
|
| 2 |
| Reverse run disable |
|
|
|
|
|
|
| ||
| F 2 | [Accel pattern] | 0/1 | 0 |
| Linear | 0 |
| X |
| |||||||
| F 3 | [Decel pattern] |
|
| 1 |
|
|
|
|
|
|
|
| ||||
| F 4 | [Stop mode | 0/2 | 0 |
| Decelerate to stop | 0 |
| X |
| |||||||
|
|
| select] |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 1 |
| Stop via DC brake |
|
|
|
|
|
|
| ||
|
|
|
|
|
| 2 |
| Free run to stop |
|
|
|
|
|
|
| ||
| F 8 | [DC Brake |
| 0/60 [Hz] | |
| This parameter sets DC brake start | 5.0 |
| X |
| ||||||
| 1) | start |
|
|
| frequency. |
|
|
|
|
|
|
| ||||
|
|
| frequency] |
|
|
| It cannot be set below F23 - [Start |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| frequency]. |
|
|
|
|
|
|
| |||
| F 9 | [DC Brake | 0/60 | |
| When DC brake frequency is reached, | 0.1 |
| X |
| |||||||
|
|
| wait time] |
| [sec] |
| the inverter holds the output for the setting |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| time before starting DC brake. |
|
|
|
|
|
|
| |||
| F10 | [DC Brake | 0/200 | |
| This parameter sets the amount of DC | 50 |
| X |
| |||||||
|
|
| voltage] | [%] |
| voltage applied to a motor. |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| It is set in percent of H33 – [Motor rated |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| current]. |
|
|
|
|
|
|
| |||
| F11 | [DC Brake | 0/60 | |
| This parameter sets the time taken to | 1.0 |
| X |
| |||||||
|
|
| time] |
| [sec] |
| apply DC current to a motor while motor is |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| at a stop. |
|
|
|
|
|
|
| |||
| F12 | [DC Brake | 0/200 | |
| This parameter sets the amount of DC | 50 |
| X |
| |||||||
|
|
| start voltage] | [%] |
| voltage before a motor starts to run. |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| It is set in percent of H33 – [Motor rated |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| current]. |
|
|
|
|
|
|
| |||
| F13 | [DC Brake | 0/60 | |
| DC voltage is applied to the motor for | 0 |
| X |
| |||||||
|
|
| start time] |
| [sec] |
| DC Brake start time before motor |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| accelerates. |
|
|
|
|
|
|
| |||
| F14 | [Time for | 0/60 | |
| This parameter applies the current to a | 1.0 |
| X |
| |||||||
|
|
| magnetizing a |
| [sec] |
| motor for the set time before motor |
|
|
|
|
|
|
| |||
|
|
| motor] |
|
|
| accelerates during Sensorless vector |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| control. |
|
|
|
|
|
|
| |||
| 1) | : Set F4 | to 1 (Stop via DC brake) to view this function |
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| F20 | [Jog |
| 0/400 | |
| This parameter sets the frequency for | 10.0 |
| O |
| ||||||
|
|
| frequency] |
| [Hz] |
| Jog operation. |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| It cannot be set above F21 – [Max |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| frequency]. |
|
|
|
|
|
|
| |||
| F21 | [Max |
| 40/400 * |
| |
| This parameter sets the highest |
| 60.0 |
| X |
|
| |||
|
|
| frequency] |
| [Hz] |
|
| frequency the inverter can output. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| It is frequency reference for Accel/Decel |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| (See H70) |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| If H40 is set to 3 (Sensorless vector), it |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| can be settable up to 300Hz *. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| Caution : Any frequency cannot be set |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| above Max frequency. |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| F22 | [Base |
| 30/400 |
| |
| The inverter outputs its rated voltage to |
| 60.0 |
| X |
|
| |||
|
|
| frequency] |
| [Hz] |
|
| the motor at this frequency (see motor |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| nameplate). In case of using a 50Hz motor, |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| set this to 50Hz. |
|
|
|
|
|
|
| ||
| F23 | [Start |
| 0/10 |
| |
| The inverter starts to output its voltage at |
| 0.5 |
| X |
|
| |||
|
|
| frequency] |
| [Hz] |
|
| this frequency. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| It is the frequency low limit. |
|
|
|
|
|
|
|
44