Chapter 9. Basic functions

9.7Frequency limit setting

z Frequency limit setting based on Max and start frequency

 

 

 

 

 

 

 

 

 

 

 

 

Group

 

 

LED display

 

 

Parameter name

 

 

Set

 

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

 

 

 

 

 

 

 

value

 

 

 

range

 

 

defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

F21

 

 

[Max frequency]

 

-

 

0/400

 

60.0

 

 

Hz

 

group 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F23

 

 

[Start frequency]

 

-

 

0/10

 

0.5

 

 

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒ Max frequency: Frequency high limit except for F22 [Base frequency]. Any frequency cannot be set above [Max frequency].

ƒ Start frequency: Frequency low limit. If a frequency is set lower than this, 0.00 is automatically set.

z Run frequency limit based on frequency High/Low limit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group

 

 

LED Display

 

 

Parameter Name

 

 

Set

 

 

 

Min/Max

 

 

Factory

 

 

Unit

 

 

 

 

 

 

 

 

 

Value

 

 

 

Range

 

 

Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

F24

 

 

[Frequency High/Low

 

 

1

 

0/1

 

0

 

 

 

 

 

group 1

 

 

 

limit select]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F25

[Frequency high limit]

 

-

 

0/400

 

60.0

 

 

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F26

[Frequency low limit]

 

-

 

0/400

 

0.5

 

 

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ƒSet F24 to 1.

ƒActive run frequency can be set within the range set in F25 and F26.

When frequency setting is done via Analog input (voltage or current input), the inverter operates within the range of high and low limit frequency as shown below.

This setting is also valid when frequency setting is done via keypad.

When freq. limit is not

Freq.selected

High limit

Max freq.

freq.

 

 

Low limit

 

 

freq.

10V

V1(Voltage input)

 

0

20mA

I (Current input)

77

Page 77
Image 77
LG Electronics C Series manual Frequency limit setting, F24 Frequency High/Low, Limit select