Chapter 2. Installation
2.1 Installation precautions
CAUTION
zHandle the inverter with care to prevent damage to the plastic components. Do not hold the inverter by the front cover. It may fall off.
zInstall the inverter in a place where it is immune to vibration (5.9 m/s2 or less).
The inverter is under great influence of ambient temperature
zInstall in a location where temperature is within the permissible range
Maximum Surrounding Air Temperature is 50°C (122°F) without
5cm | 5cm |
1.97 in | 1.97 in |
| 1.97 in |
| 5cm |
<Ambient Temp Checking Location>
zThe inverter will be very hot during operation. Install it on a
zMount the inverter on a flat, vertical and level surface. Inverter orientation must be vertical (top up) for proper heat dissipation. Also leave sufficient clearances around the inverter.
3.94in 10cm Min
1.97in 1.97 in
5cm |
|
|
|
|
| 5cm | ||||||||
|
| 3.94 in |
|
|
|
|
| Min | ||||||
Min |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10cm Min | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Leave space enough to allow cooling air to flow easily between wiring duct and the unit
Cooling air
Ventilating fan
zProtect from moisture and direct sunlight.
zDo not install the inverter in any environment where it is exposed to water drops, oil mist, dust, etc. Install the inverter in a clean place or inside a “totally enclosed” panel, which does not accept any suspended matter.
13