2CLI Commands
McDATA OPENconnectors Command Line Interface USER MANUAL P/N 620-000134-300
2-48
FRQILJ]RQLQJUHQDPH=RQH6HW
6\QWD[ renameZoneSet zoneSetName
3XUSRVH This command changes the name of the zone set in the work area.
'HVFULSWLRQ Changes are not activated on the switch until the
config.zoning.activateZoneSet command is issued.
3DUDPHWHUV This command has one parameter.
&RPPDQG([DPSOH Root> config zoning renameZoneSet TheUltimateZoneSet
FRQILJ]RQLQJDGG:ZQ0HP
6\QWD[ addWwnMem zoneName wwn
3XUSRVH This command adds a WWN zone member to the specified zone in
the work area.
'HVFULSWLRQ The CLI supports the number of zones members per zone specified
for a given product.
3DUDPHWHUV This command has two parameters.
&RPPDQG([DPSOH Root> config zoning addWwnMem TheUltimateZone
10:00:00:00:C9:22:9B:64
zoneSetName Specifies the new name for the zone set. The
zoneSetName must contain 164 characters.
Valid characters are:
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdef
ghijklmnopqrstuvwxyz0123456789$-^_
Spaces are not permitted, and the first character
must be alphabetical.
zoneName Specifies the name of the zone.
wwn The WWN of the member to be added to the
zone. The value of the WWN must be in
colon-delimited hexadecimal notation (for
example, AA:00:AA:00:AA:00:AA:00).