CRS-300 1:10 Redundancy Switch

Revision 16

Modem, RMI/TMI, and Switch Configuration

MN/CRS300.IOM

5.2.4.3Switch to CDM-700, CDM-710, CDM-710G Redundancy Configuration

Only the Rev. A chassis (i.e., chassis with round-buttoned keypad) and later versions of the CDM-700/710 offer 1:N redundancy operation.

IMPORTANT

The CRS-300 communicates to the Redundant and Traffic modems via a serial TTL bus contained within the CDM-700/710/710G DB-15 “Alarms” connector on the modem back panel.

ADB-15 to HD-15 Control Cable connects each modem to the CRS-300. To configure the CDM-700/710/710G and CRS-300 for 1:N redundancy:

Step Procedure

1If the terrestrial data type is Ethernet, for each modem, enter a unique IP Address for the CDI-70 (GigE Interface) that is on the same subnet:

For the CDM-700: CONFIG Æ Intfc1 Æ MAN Æ ADDRESS

For the CDM-710 or CDM-710G: CONFIG Æ Intfc2 Æ MAN Æ ADDRESS

2 The DB-15 “Alarms” connector on the modem back panel must be configured for “Redundancy Mode”. On each modem, set the redundancy to the Active state:

CONFIG Æ AUX (Redundancy Mode) Æ ENA/DIS set to Enable.

Press ENT to save parameters to flash memory. The CDM-700/710/710G modems do not have any further COMM menus configured by the User.

3 Power down all CDM-700s/710s/710Gs.

4 Power up all CDM-700s/710s/710Gs. Verify that each Traffic Modem is ONLINE via the front panel LEDs.

All configuration changes can only be made to the Online CDM-700/710/710G and will require the User to “Save Parameters to permanent storage” to ensure

IMPORTANT the configuration change is also applied to the Backup CDM-700/710/710G.

Refer to the CDM-700, CDM-710, or CDM-710G Installation and Operation Manuals for detailed configuration information.

5–5