CRS-300 1:10 Redundancy Switch Remote Control

Revision 16 MN/CRS300.IOM

 

Command

Parameter Type

(Code and

 

qualifier)

 

 

Retrieve Next 5

N/A

unread Stored

 

Events

 

Arguments for

Command or Response to Query

80 bytes

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Query only.

Switch returns the oldest 5 Stored Events, which have not yet been read over the remote control.

Reply format: [cr]Sub-body[cr]Sub-body[cr]Sub-body[cr]Sub-body[cr]Sub- body, where Sub-body = KLMddmmyyhhmmss

K is the fault/clear indicator, where F = Fault, C = Clear, I = Info

L is the faulting/clearing unit, where the values can be: 1,2,...9 indicating traffic modems 1,2...9, A=modem 10,

B=Redundant Modem C=Switch

D=Info

M is the fault code, where value depends on faulting unit: Switch codes are 1 to F, indicating the position (1-15) of

the fault within the Switch FLT string. Modem codes are:

1= Unit, 2= Rx traffic, 3= Tx traffic Info codes are:

0= Power off, 1= Power on, 2= Log cleared

ddmmyy is the date of the event (international format). hhmmss is the time of the event.

If there are no new events, the unit replies with RNE*.

If fewer than 5 events remain, the last positions are filled with zeroes.

Response to Command (Target-to-Controller)

N/A

 

Query

 

 

Response to query

 

 

(Code and

 

 

 

 

 

 

(Target-to-Controller)

 

 

qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RNE?

RNE=[cr]KLMddmmyyhh

 

 

 

mmss[cr]KLMddmmyyhh

 

 

 

mmss[cr]KLMddmmyyhh

 

 

 

mmss[cr]KLMddmmyyhh

 

 

 

mmss[cr]KLMddmmyyhh

 

 

 

mmss

 

 

 

(see Description of

 

 

 

Arguments)

Restore Holdoff

RSH=

2 bytes, numerical

Time

 

 

Command or Query.

The restore holdoff time is the delay when auto mode prepares to return a modem (previously faulted, now good) back online due to a different Traffic Modem’s failure, where:

01-99 = # of seconds after offline Traffic Modem lost its fault before it is put back online so that Redundant Modem can bridge the newly faulted modem.

RSH= (message OK)

RSH? (received OK, but invalid arguments found)

RSH# (message OK, # (message OK, but only permitted in Remote mode)

RSH?

RSH=xx

 

(see Description of

 

Arguments)

C–11

Page 261
Image 261