CRS-300 1:10 Redundancy Switch Remote Control

Revision 16 MN/CRS300.IOM

 

Command

Parameter Type

(Code and

 

qualifier)

 

 

Switch Alarm

SAM=

Mask

 

Arguments for

Command or Response to Query

1 byte, numerical

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Command or Query.

Where x indicates the Switch alarm mask: 0 = no faults masked

1 = PSU-A faults masked

2 = PSU-B faults masked

Response to Command (Target-to-Controller)

SAM= (message OK) SAM? (received OK, but invalid arguments found) SAM# (message OK, but only permitted in Remote mode)

 

Query

 

Response to query

 

 

(Code and

 

 

 

 

(Target-to-Controller)

 

 

qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

SAM?

SAM=x

 

 

 

(see Description of

 

 

 

Arguments)

SwitchDataTime

SDT=

1 byte, numerical

Switch Global

SGC=

29 bytes,

Configuration

 

numerical

Switch ID

SID=

24 bytes, ASCII

Command or Query.

This command allows the Switch to send commands to all attached modems on a daily basis to set their time and date values to the same as the Switch. This value is also saved in nonvolatile memory to retain setting during a power outage. The factory default setting is SDT=0.

SwitchDataTime, where x where:

0 turns off this feature.

1 enables this feature

Example: SDT=1

Command or Query.

Global configuration of the Switch, in the form: OaaaaaaaaaaBNNbbrrMSAssssssss, where: O = Operating Mode – same as OPM (1 bytes) a = Active Modems – same as ACT (10 bytes)

B = Bridge/Backup State – same as BBU (1 byte) N = Selected TM Number - same as BBU (2 bytes) b = Backup Holdoff Time – same as BKH (2 byte) r = Restore Holdoff Time – same as RSH (2 byte) M = Modem Alarm Mask – same as MAM (1 byte) S = Switch Alarm Mask – same as SAM (1 byte) A = Audio Alarm Mask – same as AAM (1 bytes) P = Priority mode – same as PRI

s = 7 spare bytes

Command or Query.

A user-defined Switch ID, which is a fixed length of 24 characters.

Valid characters include: Space ( ) * + - , . / 0-9 and A-Z.

SDT= (message OK) SDT? (received OK, but invalid arguments)

SDT* (message OK, but not permitted in current mode)

SGC= (message OK) SGC? (received OK, but invalid arguments found) SGC# (message OK, but only permitted in Remote mode)

SID= (message OK)

SID? (received OK, but invalid arguments found)

SID# (message OK, but only permitted in Remote mode)

SDT?

SDT=xx

 

(see Description of

 

Arguments)

SGC?

SGC=OaaaaaaaaaaBNN

 

bbrrMSAPsssssss

 

(see Description of

 

Arguments)

SID?

SID=xxxxxxxxxxxxxxxxx

 

xxxxxxx

 

(see Description of

 

Arguments)

C–12

Page 262
Image 262
Mocomtech CRS-300 Parameter Type Code Qualifier Switch Alarm, Mask Arguments for Command or Response to Query, SAM=x