Mocomtech CRS-300 operation manual Rear Panel, Modem Interface Cards CDM-570/570L, -600/600L

Models: CRS-300

1 266
Download 266 pages 34.55 Kb
Page 30
Image 30

CRS-300 1:10 Redundancy Switch

Revision 16

Introduction

MN/CRS300.IOM

1.4.2Rear Panel

Figure 1-4shows the back panel of the CRS-300 with a typically configured mix of TMI cards.

Because the RMI can have the capability for several TMIs, depending on user requirements the CRS-300 may be able to use several different TMI cards

NOTE simultaneously.

CRS-306

(2X) Unused

(6X) CRS-325

(2X) CRS-336

RMI

Blanks

TMI

TMI

CRS-250

CRS-230

CRS-250

Power Supply Module

System Controller

Power Supply Module

Figure 1-4. CRS-300 Rear Panel – Configuration Example

1.4.3Modem Interface Cards: CDM-570/570L, -600/600L, -625

The following tables indicate which TMI (Traffic Modem Interface) cards and which RMI (Redundant Modem Interface) cards should be used with each modem and data type:

CDM-570/570L Modems

 

Data Type

TMI Type

 

RMI Type

 

G.703 T1/E1 Bal/Unbal

CRS-330 or CRS-340

 

CRS-310

 

 

 

 

 

EIA-422, V.35, EIA-232

CRS-340

 

 

 

 

 

 

 

 

 

CDM-600/600L Modems, CDM-625 Modem (in CDM-600 Emulator Mode)

Data Type

 

TMI Type

 

RMI Type

G.703

Bal (DDI, IDO, DDO, IDI) Notes 1, 2

 

CRS-330

 

 

G.703

Unbal (DDI, IDO, DDO, IDI) Notes 1, 2

 

 

 

EIA-422/V.35, EIA-232, LVDS

 

CRS-340 Note 3

 

CRS-310

G.703

Bal (DDI, IDO, DDO, IDI) Notes 1, 2

 

 

G.703 Unbal Notes 1, 2

 

 

 

 

Converts LVDS (Modem) to/from HSSI (User)

 

CRS-370

 

 

 

 

 

 

 

 

1–8

Page 30
Image 30
Mocomtech CRS-300 operation manual Rear Panel, Modem Interface Cards CDM-570/570L, -600/600L