CRS-300 1:10 Redundancy Switch

Revision 16

Addressing Scheme Information

MN/CRS300.IOM

B.3.2 Setting Up Transceivers

IMPORTANT

Configure the modems first for EDMAC operation, setting up the Remote Control Address (RCA) for local units, and ESA (EDMAC addresses) for EDMAC modems. A transceiver's address will be set automatically by its controlling modem if connected via the FSK link when the ODU enable is configured.

Local Transceiver 1 (linked to Modem m on the Switch):

oFirst, set up the modem RCA, as described in Section B.3.1.

oOn the modem, key to Enable ODU.

The modem automatically sets the transceiver address: Transceiver MCA = (Modem RCA) + 1.

Local Transceivers 1 & 2 (1:1 configuration, attached to Modem m on the Switch):

oFirst, set up the modem RCA, as described in Section B.3.1.

oOn the online modem, key to Enable ODU.

The modem automatically sets the transceiver addresses: MCA of Transceiver #1 = (Modem RCA) + 1 MCA of Transceiver #2 = (Modem RCA) + 2

Distant Transceiver 1 (stand-alone):

oFirst, set up the modems, first, as described earlier in this section. .

oOn the modem, key to Enable ODU.

The modem automatically sets the transceiver address: Transceiver MCA = (Master ESA) + 4 = (Slave ESA) + 3

Distant Transceivers 1 & 2 (1:1 configuration):

oFirst, set up the modem, as described earlier in this section.

oOn the modem, key to Enable ODU.

The modem automatically sets the transceiver addresses: MCA of Transceiver #1 = (Master ESA) + 4 MCA of Transceiver #2 = (Master ESA) + 5

B.4 M&C Applications

The system is set up such that it may be communicated to by an M&C application, e.g., SatMac or CMCS. In the SatMac application, go to the Link Edit Mode screen to enter the Monitor & Control Addresses (MCA).

B–12

Page 250
Image 250
Mocomtech CRS-300 operation manual Setting Up Transceivers, M&C Applications