CRS-300 1:10 Redundancy Switch

Revision 16

Connector Pinouts

MN/CRS300.IOM

6.1.4System Alarms – DB-25F Connector

Table 6-3indicates the pinout for the DB-25F TMI System Alarms connector.

Table 6-3. System Alarms Connector

Pin Description by Mode of Operation

Pin

“Show Fault” when Switch loses power (Default)

“Show No-Fault” when Switch loses power

 

 

 

1Traffic Modem Online Status – Common Common for pins 2-6 and 14-18

14Traffic Modem #10 Online Status – Normally Open (Note 2)

2 Traffic Modem #9 Online Status – Normally Open (Note 2)

15Traffic Modem #8 Online Status – Normally Open (Note 2)

3 Traffic Modem #7 Online Status – Normally Open (Note 2)

16Traffic Modem #6 Online Status – Normally Open (Note 2)

4

Traffic Modem #5 Online Status – Normally Open (Note 2)

Unchanged

 

17 Traffic Modem #4 Online Status – Normally Open (Note 2)

 

 

5Traffic Modem #3 Online Status – Normally Open (Note 2)

18 Traffic Modem #2 Online Status – Normally Open (Note 2)

6Traffic Modem #1 Online Status – Normally Open (Note 2)

19 No Connection

7Ground

20 Audio Indicator (Gnd = Auto On / Float = Audio Off)

8Form C Fault Relay – Common Common for pins 9-13 and 21-24

21

Switch Unit Fault – Normally Closed

Switch Unit Fault – Normally Open

9

Switch Unit Fault – Normally Open

Switch Unit Fault – Normally Closed

22

Modem Summary Unit Fault –Normally Closed

Modem Summary Unit Fault –Normally Open

10

Modem Summary Unit Fault – Normally Open

Modem Summary Unit Fault – Normally Closed

23

Modem Summary Tx Traffic Fault – Normally Closed

Modem Summary Tx Traffic Fault – Normally Open

11

Modem Summary Tx Traffic Fault – Normally Open

Modem Summary Tx Traffic Fault – Normally Closed

24

Modem Summary Rx Traffic Fault – Normally Closed

Modem Summary Rx Traffic Fault – Normally Open

12

Modem Summary Rx Traffic Fault – Normally Open

Modem Summary Rx Traffic Fault – Normally Closed

25

Modem Summary DFM Fault – Normally Closed

Modem Summary DFM Fault – Normally Open

13

Modem Summary DFM Fault – Normally Open

Modem Summary DFM Fault – Normally Closed

Notes:

1.“Normally” refers to the NON-FAILED state.

2.Traffic Modem Online Status (Open = Online, Closed = Backup)

6–3

Page 171
Image 171
Mocomtech CRS-300 operation manual System Alarms DB-25F Connector, System Alarms Connector