CRS-300 1:10 Redundancy Switch

Revision 16

Cables and Connections

MN/CRS300.IOM

4.11 IF Cable Connections

There are two different possible IF configurations: single transponder and multiple transponders.

1.For a single transponder, all the modems are connected to the same user Up/Downconverter.

2.For multiple transponders, the modems may be grouped and connected in various combinations to multiple up/down converters. The CRS-280 (70/140 MHz) IF Switch is required for multiple transponder operation.

If using the CRS-280L (L-Band) IF Switch, additional installation information can be found in the CRS-280L Installation and Operation Manual.

Proceed with the transponder configuration method applicable to your system.

4.11.1 IF Cable Connections – Single Transponder (without CRS-280/280L)

To prevent problems resulting from impedance mismatch, ensure that the impedance for the modem’s cables and combiner are the same.

IMPORTANT

Referring to Figure 4-36(L-Band operation shown):

For single transponder IF configurations, connect the user-provided IF cables as follows:

For Transmit (Tx) IF Connections:

Connect the appropriate user-provided IF cables from each modem’s “Tx IF” connector (BNC for 70/140 MHz, Type ‘N’ for L-Band) to a single user-provided power combiner.

Connect the output of the power combiner to the user Upconverter.

For Receive (Rx) IF Connections:

Connect the appropriate (BNC for 70/140 MHz, provided splitter.

user-provided cables from each modem’s “Rx IF” connector Type ‘N’ for L-Band) to the output ports of a single user-

Connect the input of the splitter to the output of the user Downconverter.

When a modem is taken offline, its Tx IF is automatically muted (shut down) by the CRS-300.