CRS-300 1:10 Redundancy Switch Remote Control

Revision 16 MN/CRS300.IOM

 

Command

Parameter Type

(Code and

 

qualifier)

 

 

Serial Number

N/A

 

 

Software

N/A

Revision

 

Arguments for

Command or Response to Query

9 bytes, numerical

4 bytes, numerical

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Query only.

Unit returns its 9-digit serial number.

Example: SNO=176512523

Query only.

Unit returns the value of internal software revision installed in the unit, in the form x.xx

Example: SWR=1.03 (Ver 1.03)

Response to Command (Target-to-Controller)

N/A

N/A

 

Query

 

 

Response to query

 

 

(Code and

 

 

 

 

 

 

(Target-to-Controller)

 

 

qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SNO?

SNO=xxxxxxxxx

 

 

 

 

(see Description of

 

 

 

 

Arguments)

 

 

SWR?

SWR=x.xx

 

 

 

 

(see Description of

 

 

 

 

Arguments)

Time

TIM=

6 bytes, numerical

Command or Query.

The time from midnight, in the form hhmmss, where hh = hours, between 00 and 23,

mm= minutes, between 00 and 59, and ss = seconds, between 00 and 59

Example: TIM=231259 would be 23 hours, 12 minutes and 59 seconds from midnight.

TIM= (message OK) TIM? (received OK, but invalid arguments) TIM# (message OK, but only permitted in Remote mode)

TIM?

TIM=hhmmss

 

(see Description of

 

Arguments)

C–13

Page 263
Image 263
Mocomtech CRS-300 operation manual Sno?