CRS-300 1:10 Redundancy Switch

Revision 16

Cables and Connections

MN/CRS300.IOM

The choices from this display are:

Normal: CDM-625

Emulate: CDM-600, and

Emulate: CDM-600L.

Once the desired emulation mode is selected, press the ENT button to save the configuration.

4.5.6.2Control and Data Connections – CRS-300 to Modems in CDM-600/600L Emulation Mode

For each CDM-625 that replaces a CDM-600/600L modem: Refer to Figure 4-15to connect and secure the CA/WR Control/Data Cable cables between each CDM-625 and the CRS-300 as follows:

DB-25M connector labeled “P1” on the RMI or TMI(s), to

DB-25F connector labeled “Data Interface” on the CDM-625.

For all system configurations and cable interconnection of the various traffic data types available for the CDM-625 in this operational mode, refer to Chapter 4.5.1 Control and Data Connections – CRS-300 to Modems for specific details.

Figure 4-14. Cabling Example for CRS-350 to CDM-625

(Connections shown for RMI and TMI 1 only)

4–36