CRS-300 1:10 Redundancy Switch

Revision 16

Modem, RMI/TMI, and Switch Configuration

MN/CRS300.IOM

Furthermore, in Ethernet Bridge Mode, the parameter backup mechanism is unsupported; therefore, the User must make sure that all parameters match in the Online and Offline modems.

Refer to the SLM-5650 or SLM-5650A Installation and Operation Manual for detailed configuration information.

5.2.4.4.3Ethernet Bridge Mode Configuration via Optional GbE Interface

Due to backplane limitations, the CRS-300 can support Single-port Ethernet Bridge Mode only. Ethernet Bridge Mode redundancy, when using SLM-5650/5650 modems equipped with the optional 10/100/1000 Base-T (GbE) Interface, is provided by a Single IP Address scheme.

To configure the SLM-5650/5650A for Ethernet Bridge Mode 1:1 redundancy, for each modem enter a unique IP Address for the optional 10/100/1000 Base-T (GbE) Interface card that is on the same subnet:

CONFIG Æ MODE Æ INTERFACE Æ GIGABIT ETHERNET

Refer to the SLM-5650 or SLM-5650A Installation and Operation Manual for detailed configuration information.