CRS-300 1:10 Redundancy Switch

Revision 16

Introduction

MN/CRS300.IOM

1.6Summary of Specifications

1.6.1CRS-300 Specifications

 

Characteristic

 

 

Requirement

 

 

 

 

 

 

 

 

Switch Type

 

1:N Redundancy Switch system ( N=10 max), Bridging architecture

 

 

 

C161 control processor

 

 

 

 

 

 

 

 

 

 

CDM-570/570L

 

 

 

 

 

CDM-600/600L

 

 

 

 

 

CDM-625

 

 

Compatible Modems

 

CDM-Qx/QxL

 

 

 

CDM-700

 

 

 

 

 

 

 

 

 

 

CDM-710

 

 

 

 

 

CDM-710G

 

 

 

 

 

SLM-5650/5650A

 

 

 

 

 

Fully automatic or manual

 

 

Operating Modes

 

Force traffic modem to redundant modem

 

 

 

Remove selected traffic modem from control

 

 

 

 

 

 

 

 

 

 

Programmable holdoff-to-backup and holdoff-to-restore (from 1 to 99 seconds)

 

 

Switching Conditions

 

Switch to redundant modem following a Unit fault, Tx or Rx traffic faults

 

 

Switching Time

 

9 seconds max. (Delay interval set to minimum, 1 sec)

 

 

 

 

 

CRS-300 without CRS-280/280L IF Switch: IF ON / OFF control through the

 

 

IF Switching

 

 

Switch controller.

 

 

 

 

 

CRS-300 with CRS-280/280L: all modems outputs ON all the time.

 

 

Temperature

 

0 to +50°C (32 to 122°F) Operating

 

 

 

 

 

50 to 100°C (122 to 212°F) Storage

 

 

Humidity

 

95% at +40°C (104°F), Non-condensing

 

 

CE Mark

EMC and Safety

 

 

Environmental

 

Operating temperature range: 0° to 40°C (32° to 104°F)

 

 

AC Prime Power

 

Two independent inputs: 100 to 250 VAC, 50/60 Hz, at 25 watts VA max

 

 

 

 

 

 

DC Prime Power

48 (38 to 60) VDC 25 watts max

 

 

 

 

 

 

 

 

 

Redundant Modem

 

Any one of the 10 traffic paths (bridge mode) (both Rx IF and Tx data)

 

 

Signal Source

 

 

 

 

 

 

 

 

 

 

 

 

Vacuum Fluorescent Display (VFD): 2 lines @ 24 characters/line.

 

 

 

 

 

6-button Keypad: ENT (Enter), CLR (Clear), (4X) navigation

 

 

Front Panel

 

LED system status display showing, for all modems:

 

 

 

 

o Unit fault, Rx traffic fault

 

 

 

 

 

 

 

 

 

 

 

 

o Tx traffic alarm Online / Offline status

 

 

 

 

 

 

o Bridge status

 

 

Audible Alarm

 

Programmable to activate following various changes of state

 

 

 

 

 

 

Common faults

Dry relay contacts

 

 

 

 

 

 

Dimensional Envelope

19W x 11.75D x 6.75H inch (48.26W x 29.85D x 17.15H cm) (4RU)

 

 

 

 

 

 

 

Weight

 

~ 20 lbs (~ 9.07 kg)

 

 

 

 

 

 

 

 

 

1–16

Page 38
Image 38
Mocomtech operation manual Summary of Specifications CRS-300 Specifications, Characteristic Requirement