CRS-300 1:10 Redundancy Switch

Revision 16

Front Panel Operation

MN/CRS300.IOM

7.4.4 CONFIG: REMOTE

SELECT REMOTE CONTROL:

LOCAL REMOTE (PRESS ENT)

Select LOCAL or REMOTE using the ◄ ► arrow keys, then press [ENT].

CONFIG: REMOTE Æ LOCAL

If LOCAL is selected, remote control will be disabled, though remote monitoring is always possible.

CONFIG: REMOTE Æ REMOTE

If REMOTE is selected:

REMOTE CONTROL: BAUDRATE

INTERFACE (PRESS ENTER)

Select BAUDRATE or INTERFACE, using the ◄ ► arrow keys, then press [ENT].

CONFIG: REMOTE Æ REMOTE Æ BAUDRATE

If BAUDRATE is selected:

EDIT SWITCH BAUDRATE: 19200 BAUD (PRESS ENT)

The User may select the baud rate of the remote control bus, connected locally to the M&C computer. Change the value by using the ▲ ▼ arrow keys. Values of 300, 1200, 2400, 4800, 9600 and 19200 baud are possible.

Once baudrate has been set, the User should pres ENT.

Note: This setting does not affect the internal communications between the Switch and the modems.

CONFIG: REMOTE Æ REMOTE Æ INTERFACE

If INTERFACE is selected:

ELECT. INTERFACE: RS232

RS485-2W RS485-4W (ENT)

Select RS232, RS485-2W(2-wire), or RS485-4W(4-wire) using the ◄ ► arrow keys, then press [ENT]. The User will be further prompted to enter the bus address.

In this example, RS-232 mode is used and the bus address is fixed at 0:

IN RS232 MODE THE BUS

ADDRESS IS FIXED AT 0000

If in RS-485, the address may be selected. The valid addresses are 1000, 3000, 5000 and 7000 only, as explained in Appendix C. REMOTE CONTROL in this manual.

7–11

Page 191
Image 191
Mocomtech CRS-300 operation manual Config Remote