CRS-300 1:10 Redundancy Switch Remote Control

Revision 16 MN/CRS300.IOM

 

Command

Parameter Type

(Code and

 

qualifier)

 

 

Config Load

CLD=

Arguments for

Command or Response to Query

1 byte, numerical,

0 to 9

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Command only.

Forces the Switch to retrieve the Configuration Memory location defined by the argument (0 to 9) and to re-program the Switch with that stored configuration.

Response to Command (Target-to-Controller)

CLD= (message OK) CLD? (received OK, but invalid arguments found) CLD* (message OK, but the memory location does not contain configuration info)

 

Query

 

Response to query

 

 

(Code and

 

 

 

 

(Target-to-Controller)

 

 

qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

N/A

N/A

Config Store

CST=

1 byte, numerical,

 

 

0 to 9

Date

DAY=

6 bytes, numerical

Equipment ID

N/A

4 bytes,

 

 

alphanumeric

Command or Query.

The command forces the Switch to store the its current configuration in Configuration Memory location defined by the argument (0 to 9).

Example: CST=4 (Store current configuration in location 4)

WARNING: Use with caution! If the location already contains data, it will be automatically overwritten. If in doubt, query the location first. The query returns the contents of the location.

Command or Query.

The date, in the form ddmmyy (international date convention), where:

dd = day of the month, between 01 and 31,

mm = month of the year, between 01 and 12, and

yy= year, between 97 and 96 (1997 to 2000, then 2000 to 2096)

Example: DAY=240457 would be April 24, 2057.

Query only.

Unit returns information concerning the equipment identification.

Example: S300

CST= (message OK) CST? (received OK, but invalid arguments found) CST# (message OK, but only permitted in Remote mode)

DAY= (message OK) DAY? (received OK, but invalid arguments) DAY# (message OK, but only permitted in Remote mode)

N/A

CST?n

Returns the same format

where n is

as the SGC, with the

0 to 9

form:

 

CST=xxx....xxx for a

 

valid config, and

 

CST* where no valid

 

config is found

 

 

DAY?

DAY=ddmmyy

 

(see Description of

 

Arguments)

EID?

EID=xxxx

 

(see Description of

 

Arguments)

C–8

Page 258
Image 258