CRS-300 1:10 Redundancy Switch Remote Control

Revision 16 MN/CRS300.IOM

 

Command

Parameter Type

(Code and

 

qualifier)

 

 

Faults and Status

N/A

Arguments for

Command or Response to Query

15bytes, alphanumeric

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Query only.

Unit returns the current fault and status codes for the Switch itself, where:

r = Redundant Modem:

0 = OK

1 = RMI not present

2 = RM I/O timeout

3 = RM not in remote mode

4 = RM is in a test mode

5 = RM is rejecting MGC configuration string

6 = CDM-Qx: Interface is set for IP – No Coms available

7 = CDM-700: RM is rejecting an interface configuration string Power supply information, values 0 or 1 only.

A/a = + 5V PSU-A under/over B/b = +5V PSU-B under/over C/c = +12V PSU-A under/over D/d = +12V PSU-B under/over E/e = -12V PSU-A under/over F/f = -12V PSU-B under/over m is TMI: interface mismatch:

0 = no problem, 1-9, A (for pos 10) indicates the position of a TMI interface mismatch

i is modem I/O communications:

0 = no problem, 1-9, A (for pos 10) indicates the position of a modem which has been activated but is not responding.

Response to Command (Target-to-Controller)

N/A

 

Query

 

 

Response to query

 

 

(Code and

 

 

 

 

 

 

(Target-to-Controller)

 

 

qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLT?

FLT=rAaBbCcDdEeFfmi

 

 

 

 

(see Description of

 

 

 

 

Arguments)

Local/ Remote

LRS=

Status

 

 

 

Modem Alarm

MAM=

Mask

 

1 byte, value of 0 or 1

1 byte, numerical

Command or Query.

Where x indicates the local/remote status of the Switch: 0 = local

1= remote

Command or Query.

Where x indicates the Modem alarm mask: 0 = no faults masked

1 = Tx faults masked

2 = Rx faults masked

3 = Both Tx and Rx faults masked

LRS= (message OK) LRS? (received OK, but invalid arguments found)

MAM= (message OK) MAM? (received OK, but invalid arguments found) MAM# (message OK, but only permitted in Remote mode)

LRS?

LRS=x

 

(see Description of

 

Arguments)

 

 

MAM?

MAM=x

 

(see Description of

 

Arguments)

C–9

Page 259
Image 259
Mocomtech CRS-300 operation manual FLT=rAaBbCcDdEeFfmi, See Description, Arguments