MessageSaver User Guide
Register | Unit | Range | Default | Description |
| ||
S42 | decimal | 1 | Enables/disables the 56K auto rate. When | ||||
|
|
|
| 56K auto is disabled, fallback to V.34 is also | |||
|
|
|
| disabled. 0 = disable; 1 = enable. | |||
S43 | decimal | 1 | For testing and debugging only. Enables/ | ||||
|
|
|
| disables V.32bis | |||
|
|
|
| operation. 0 = disable; 1 = enable. | |||
S48 | decimal | 7 or 128 | 7 | Enables (7) or disables (128) LAPM | |||
|
|
|
| negotiation. The following table lists the S36 | |||
|
|
|
| and S48 configuration settings for certain | |||
|
|
|
| types of connections. |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| S48=7 | S48=128 |
|
|
|
|
|
|
|
|
|
|
|
|
| S36=0, 2 | LAPM or hangup | Do not use |
|
|
|
|
|
|
|
|
|
|
|
|
| S36=1, 3 | LAPM or async | Async |
|
|
|
|
|
|
|
|
|
|
|
|
| S36=4, 6 | LAPM, MNP, or hangup | MNP or hangup |
|
|
|
|
|
|
|
|
|
|
|
|
| S36=5, 7 | LAPM, MNP, or aysnc | MNP or async |
S89 |
|
|
|
|
|
|
|
seconds | 0, | 10 | Sets the length of time in the | ||||
|
|
|
| mode before the modem goes into standby | |||
|
|
|
| mode. A value of zero prevents standby | |||
|
|
|
| mode; a value of | |||
S108 | decimal | 6 | Selects the 56K digital loss if using the | ||||
|
|
|
| modem thru a PBX line. The default value is |
0=
1=
2=
3=
6=
7=
S109 | decimal | 1 | Selects the 56K operating mode. |
0= K56flex mode (V.90 disabled)
1= Dual mode (K56flex or V.90)
2= V.90 mode (K56flex disabled)
44