Chapter 4: Configuring your VOIP

FXS Loop Start Parameters

The parameters applicable to FXS Loop Start are shown in the figure below and described in the table that follows.

Figure 4-4: FXS Loop Start parameters

 

FXS Loop Start Interface: Parameter Definitions

Field Name

Values

Description

Dialing Options fields

 

FXS (Loop Start)

Y/N

Enables FXS Loop Start interface type.

Inter Digit Timer

1 - 10 seconds

This is the length of time that the MultiVOIP will wait between digits.

 

 

When the time expires, the MultiVOIP will look in the outbound

 

 

phonebook for the number entered and place the call accordingly.

 

 

Default = 2.

Message Waiting

--

Not applicable to –SS series MultiVOIPs.

Indication

 

 

Inter Digit

in milliseconds

The length of time between the outputting of DTMF digits.

Regeneration Time

 

Default = 100 ms.

 

 

 

FXS Options fields

 

FXS Ring Count,

1-10

Maximum number of rings that the MultiVOIP will issue before giving

FXS

 

up the attempted call.

Current Loss

Y/N

When enabled, the MultiVOIP will interrupt loop current in the FXS

 

 

circuit to initiate a disconnection. This tells the device connected to the

 

 

FXS port to hang up. The Multi-VOIP cannot drop the call; the FXS

 

 

device must go on hook.

Generate Current

Y/N

When selected, this option implements Answer Supervision and

Reversal

 

Disconnect Supervision to the FXO interface using current reversal to

 

 

indicate events. Applicable only when FXS and FXO interfaces are

 

 

connected back to back.

Table is continued on next

page…

 

Multi-Tech Systems, Inc.

41

Page 41
Image 41
Multi-Tech Systems MVP210/410/810-FX manual FXS Loop Start Parameters, Field Name Values Description Dialing Options fields