Chapter 3: Software Installation
Interface
The Interface Parameters are the telephony settings that are to be applied to the individual MultiVOIP channels. Configure each channel for the type of interface you are using. Channel 1 is selected by default.
Note: Feature options are enabled or unavailable depending on the selected interface type. The one option available for all interface types is the inter digit timer option. This option defines the maximum amount of time that the unit will wait before mapping the dialed digits to an entry in the phone book database. If too much time elapses between digits, and the wrong numbers are mapped, you will hear rapid busy signal. If this happens, hang up and dial again.
If the Interface Type is FXS (Loop Start), a station device such as an analog telephone, fax machine or KTS (Key Telephone System) is connected to an analog channel. The FXS options group is active.
If the Interface Type is FXO, the Dialing Options Regeneration, Flash Hook Timer and Ring Count groups are enabled. The FXO Ring Count allows you to set the number of rings before the unit answers the incoming call. Check with your local
If the Interface Type is E & M, you are connecting to an analog E & M trunk on your PBX. Check with your in- house phone personnel to determine the signaling type (Dial Tone or Wink) and if it is
Figure 3-9: Interface Parameters
23 |