Chapter 3: Software Installation

Actions:

Select Channel

oSelect Interface Type: FXS, FXO, E&M or DID (FXS/FXO only for –SS and –FX series) o Regeneration

ƒChoose how signal is regenerated; as Pulse or DTMF o Inter Digit Timer

ƒTime the MultiVOIP waits between digits

oMessage Waiting Indication is for E&M only

ƒChoose Light or None

oInter Digit Regeneration Timer

ƒLength of time between sent DTMF digits

Flash Hook Options

oGeneration (used in conjunction with FXO/E&M)

oDetection Range (used in conjunction with FXS/E&M)

Caller ID

oBellcore is the only option available

oCallerID Manipulation is available if needed

oCID Manipulation is not available in the –SS models

Pass Through (opens an audio path through the MultiVOIP)

FXS Options

oSet Ring Count (the number of rings allowed before call abandoned; default is 8)

oUse Current Loss (MultiVOIP interrupts current to disconnect)

oGenerate Current Reversal (activates Answer/Disconnect Supervision to FXO)

FXO Options

oRing Count (set number of rings before MultiVOIP answers)

oNo Response Timer (set time to attempt call before abandoning)

oSupervision Button (for call answering and disconnection settings)

ƒAnswer Fields:

Current Reversal (use current reversal to answer)

Answer Delay

Answer Delay Timer (in seconds)

Tone Detection (allow tone sequence to disconnect)

Available Tones

Answer Tones (shows current selection from Available Tones)

ƒDisconnect Fields

Current Reversal (use current reversal to disconnect)

Current Loss (loss of current will trigger disconnect)

Current Loss Timer (time after current loss to disconnect; in milliseconds)

Silence Detection Enable (use silence detection to disconnect)

Silence Detection Type (one-way or two-way)

Silence Timer (time of silence needed to trigger disconnect; in seconds)

DTMF Tone (use tones to disconnect)

Disconnect Tone Sequence (select tone pairs to use for disconnecting)

Tone Detection (disconnect from termination of tone)

Available Tones

Disconnect Tones (shows current selection from Available Tones)

E&M Options (not supported by –SS and –FX series)

oType

oMode (2-wire or 4-wire)

oSignal (Dial Tone or Wink)

oWink Timer (range is 100 to 350 milliseconds; default is 250)

oNo Response Timer (time, in seconds, after which an FXO call would be disconnected)

oDisconnect on Call Progress Tone (allows disconnection when PBX issues call progress tone)

oPass Through Enable (creates an open audio patch; not for use with Wink signaling)

DID Options (not supported by –SS and –FX series)

oStart Modes (Immediate, Wink or Delay Dial)

oWink Timer (in milliseconds)

Multi-Tech Systems, Inc.

24

Page 24
Image 24
Multi-Tech Systems MVP210/410/810-SS, MVP210/410/810-FX manual CID Manipulation is not available in the -SS models