Chapter 7: Programming 7-21

Active Time (Minutes)

You can program specific lengths of time that your NCR 7870 Scanner/Scale stays on after the last good read. There are four options in the Active Time parameter: no shut down, shut down after 15 minutes, shut down after 30 minutes, and shut down after 60 minutes. Select these times using the Hex 0 through Hex 3 tags, respectively. The default time is 15 minutes. Selecting no shut down results in the scanner/scale being active all the time.

Note: NCR suggests that you do not set the Active Time parameter to “no shut down.” Leaving the laser light on all the time reduces its life expectancy.

Program Example

Following is an example of a completed Timer programming worksheet. In this example the time-outs are programmed for the following.

Lockout Time – 900 milliseconds

Restart Lockout Timer – off

Active Time – 30 minutes

Your Program

1 2

Timers

A

B

C

3 0 2

Lockout Restart Active

Time Timer Time

11814