3-10 Chapter 3: Site Preparation

Wiring Considerations

U.S., Canadian, and Japanese Checkstand Wiring

Input Voltage

L3

G

N

Conduit

Belt Control

Belt

Lighting

Motor

Misc. Equip.

 

Neutral and Ground Bus

Main Service

Panel

Circuit A: Checkstand

Checkstand

Frame

Note: The electrical wiring must meet all electrical codes, laws, and regulations.

Feeder wiring and insulated ground from main service panel to distribution panel to be run in metal conduit.

Isolated/Insulated

Circuit Breakers

 

Ground Bus

NCR circuits should be run in

 

separate metal Conduits.

 

Note: NCR circuits must be dedicated to

L1

NCR equipment or other logically

connected electronic equipment

 

 

(modems, DAA, bridges, etc.)

 

Circuit B: Terminal

L2

 

Neutral

Circuit C: Scanner/Scale

Receptacle should be easily

Bus

accessible and near the

 

Distribution Panel

Scanner/Scale

 

 

Isolated Ground Receptacles

Installation Type

Input Voltage

L1, L2

Circuit Breakers

 

 

 

 

U.S., Canada, &

100Vac to 120Vac

100Vac to 120Vac

Standard single-pole; value

Japan

 

 

determined by type of device

 

 

 

International

220Vac to 240Vac

220Vac to 240Vac

branch and by electrical code.

 

 

 

 

European

220Vac

220Vac

European double-pole.

R0121

Page 52
Image 52
NCR 7870 manual Wiring Considerations, Canadian, and Japanese Checkstand Wiring