Chapter 8: Troubleshooting

8-3

Scale Troubleshooting Chart

Note: This information does not apply to the NCR 7870-4000 which uses a Bizerba scale. For information on troubleshooting or servicing an NCR 7870-4000 scale unit, refer to the Bizerba documentation or contact the Bizerba representative.

Problem

Possible Cause

Corrective Action

Error code 5 - - - -

Scale drift

1.

Verify nothing is on scale.

displays

 

2.

Lift Top Plate and verify no

 

 

 

 

 

objects are under it.

 

 

3.

Push Reset/Scale Zero button.

 

 

4.

Power down/up unit.

 

 

5.

If error code persists, have unit

 

 

 

repaired.

 

 

 

 

Error code 4 - - - -

Possible scale error

1.

Press Scale Zero button and retry.

displays

 

2.

If error code persists, have unit

 

 

 

 

 

repaired.

 

 

 

Error code 4 - - - -

Slight vibration to scale

Calibrate scale. Ensure there is no

displays during

during calibration

external scale movement while

calibration

 

weights are on scale.

 

 

 

 

Scale display is

Top Plate prevented

1.

Remove any interference around

blank

from moving down

 

edge of Top Plate and

 

 

 

checkstand.

 

 

2.

Remove any foreign objects from

 

 

 

under Top Plate.

 

 

3.

Push Reset/Scale Zero button.

 

 

 

Intermittent error

+12 VDC is unstable

Have 7870 repaired.

codes

 

 

 

 

 

 

 

Page 197
Image 197
NCR 7870 manual Scale Troubleshooting Chart