Image 170

7-54 Chapter 7: Programming

protocol sets the scale address to 6E; however, it may need to be changed to 6A or 6B, depending on the IBM configuration in the particular IBM customer retail application. Scan the Hex 5 tag for address 6A, the Hex 6 tag for address 6B, or the Hex 7 tag for address 6E.

The IBM terminal integrated scanner/scale driver normally uses address 6E. However, if the scanner works but the scale does not, you should try using the other two scale addresses.

9.995 kg / 13.995 kg

The 9.995 kg / 13.995 kg parameter toggles between a maximum weight of either 9.995 kg or 13.995 kg. Use the Hex B tag to toggle between the two weights.

Program Example

Following is an example of a completed Scale Parameters programming worksheet. This example shows the following programming selections.

Weight – displayed in kilograms

Unit – NCR 7870-2000 Scanner/Scale

IBM address – 6B

9.995 kg / 13.995 kg – the Hex B tag toggles this parameter

Your Program

3

0

Scale

Model

IBM

9.995 kg /

Parameters

Number

Address

13.995 kg