NCR 7870 manual Tower Subplate Assembly Cover/Lift Strap

Models: 7870

1 228
Download 228 pages 15.5 Kb
Page 81
Image 81

Chapter 4: Installation

4-7

11.Locate small plastic Cover inset in Subplate Assembly. Carefully release Cover.

Tower

Subplate Assembly

Cover/Lift Strap

11189

12.Use Cover/Lift Strap to lift the unit.

13.Position unit over checkstand cutout.

14.Lower unit into cutout.

For proper operation, the NCR 7870 must be level. It should have support within two inches of each corner to prevent rocking. Also, the leading edge of the Top Plate must be flush or up to 0.15 cm (0.06 in.) below the counter top. The trailing edge of the Top Plate must be flush with the checkstand.

Note: The four adjustable support posts on the Scale Hinge Assembly are set at the factory. Do NOT attempt to adjust the Top Plate by using these posts.

15.Replace Cover.

16.Place Top Plate on the four supports (plastic caps for scanners, rubber bumpers for scanner/scales).

17.Turn ON the unit using the circuit breaker switch.

End of Procedure