Chapter 4: Installation

4-3

Installing Unit in Checkstand

The NCR 7870 is fully assembled at the factory and requires no operator assembly. The laser module is an integral part of the factory assembled device and does not have any controls that can increase the level of laser light or collateral radiation from the NCR 7870.

Instructions

Install Cables

1.Verify power receptacle switch is off.

2.Turn NCR 7870 on its side.

3.Route power cable through groove on bottom of unit.

4.Return unit to upright position.

5.Place unit so a portion of the tower is directly over the cutout in the checkstand counter.

6.Pass Power Cord down through cutout and plug into dedicated NCR power receptacle.

7.Connect communication interface cables to host terminal or PC. Because installation varies from one terminal to another, refer to your host terminal’s documents for specific information on interface cable connection.

Note: A trained service technician may be required to open some host terminals to connect the interface cables.

8.Connect interface cables to NCR 7870. Four interface connectors are located on the rear side of the Tower Cabinet. These are for the

REMOTE DISPLAY – used to connect the NCR 7825 Remote Display, which is for price and weight information.

SCANNER (or RS-232) – used to connect interface cable on single cable installations or the scanner.