Chapter 3: Site Preparation 3-13

Wiring Instructions

Running Feeder Lines from Main Service Panel

1.Select the most appropriate wiring diagram as a guide.

2.Run two separate feeder lines in conduit from the Main Service Panel in the checkstand to the customer equipment and to the NCR Distribution Panel.

Line 1 services Circuit A which is for customer equipment such as checkstand belt motor, counter lighting, and cooling fans.

Line 2 is dedicated to service the NCR equipment, typically Circuit B and Circuit C.

Circuit A

3.Electrically connect the grounding conductor in Circuit A to Store Ground.

4.Electrically connect conduit and checkstand junction box to the frame of the checkstand, if conductive, or to a common tie point if not conductive.

5.Connect to the grounding conductor in Circuit A (which is Store Ground) any

conduit,

metal parts,

store ground devices

counter belt motor ground, and

other counter equipment grounds.