NCR 7870 manual Mode 3 Normal, OCH, xyH, xzH 43H, 3yH, 3zH OCH, 0yH, 0zH

Models: 7870

1 228
Download 228 pages 15.5 Kb
Page 178
Image 178

7-62 Chapter 7: Programming

Mode 3 – Normal

Mode 3 is the normal operating mode. You can program the scanner to add PACESETTER Plus information to the decoded UPC/EAN data that is sent to the host terminal. Perform the following procedure to enable or disable PACESETTER Plus information.

1.Scan the Programming Mode tag (must be first tag scanned after power-up).

2.Scan the Hex 3 tag.

3.Scan the Hex 1 tag.

4.Scan the Hex 3 tag.

5.Scan the Hex 1 tag to disable PACESETTER Plus information, or the Hex 2 tag to enable PACESETTER Plus information.

6.Scan the Save and Reset tag.

The PACESETTER Plus information describes the label readability much the same way as described in Mode 2. However, the host software must be capable of receiving the extra data being sent to it.

With OCIA and RS-232 communications, PACESETTER Plus information is sent as trailer information. With IBM communications, PACESETTER Plus information is sent as header information that is located between the last Status byte and the first tag data byte in the message. The PACESETTER Plus format is defined as the normal UPC/EAN format with the following added.

OCIA

RS-232

IBM

OCH, xyH, xzH

43H, 3yH, 3zH

OCH, 0yH, 0zH

x = High nibble containing character parity depending on communication format (or 0).

yz = Decoding code

Page 178
Image 178