Chapter 5: Calibration 5-11

Verifying Calibration

This section describes how to verify that the 7870 has been properly calibrated.

No error codes should appear during calibration. The codes are shown in the table below. If a code is displayed, the calibration is invalid and a corrective action must be undertaken before attempting recalibration.

Error

Problem

Suspect Component

Code

 

 

 

 

 

1 - - - -

Calibration error

Scale Board

 

A/D output below 000h at digital to

Load Cell

 

analog converter

 

 

 

 

2 - - - -

Calibration error

Scale Board

 

A/D output below 280h at digital to

Load Cell

 

analog converter

 

 

 

 

3 - - - -

Calibration error

Scale Board

 

Analog to digital converter output

Load Cell

 

too high at 15 kg (30.0 lb.)

 

 

 

 

4 - - - -

Vibration to scale during calibration

Motors in checkstand

 

 

 

9 - - - -

Interference detected during

Top Plate is touching

 

calibration

checkstand, scale was

 

 

jarred, or overload screw

 

 

is misadjusted.

 

 

 

If no error codes occur during calibration, four test procedures must be performed to verify calibration. These procedures are, in order,

Increasing Load Test ,

Over-Capacity Test,

Decreasing Load Test, and

Shift Test.