3-16 Chapter 3: Site Preparation

Service Clearance

The 7870 is designed to allow servicing without removal from the checkstand. This includes component removal and replacement, scale calibration, and installation of the Weights and Measures seal. To take advantage of this design feature, an area for service clearance must be provided.

Note: Access to the Power Supply may require removal of the 7870 from the checkstand.

Mounting surface for keyboard must be removable for servicing and vertical window replacement.

A

B

A

Item Flow Area

C

A = 20.3 cm (8.0 in.) minimum if checkstand structure is not removable for servicing. 2.5 cm (1.0 in.) minimum if checkstand structure is removable for servicing.

B = 33.0 cm (13.0 in.) minimum if checkstand structure is not removable for servicing. 17.8 cm (7.0 in.) minimum if checkstand structure is removable for servicing.

C = 13.0 cm (5.1 in.) minimum clearance to closest checkstand panel. The 7870-1000 or 2000 must not be supported by this panel.