| Troubleshooting |
|
|
| ||
|
|
| ||
| Recommended action | |||
| 0BD1 | 1st SMBus device Error | 1. | Take one of the following measures to reboot (reset) the |
|
| detected |
| modular server. |
|
|
|
| * Issue an OS command. |
|
|
|
| * Press Ctrl + Alt + Del. |
|
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
|
| Engine or NEC ESMPRO Manager. |
|
|
| 2. | Take one of the following measures to power off the modular |
|
|
|
| server and then on. |
|
|
|
| * Power off the modular server from OS, then press the |
|
|
|
| POWER/SLEEP switch to power on. |
|
|
|
| * Press the POWER/SLEEP switch to power off the modular |
|
|
|
| server, then press it again to power on. |
|
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
|
| Engine or NEC ESMPRO Manager. |
|
|
| 3. | Power off the modular server by issuing an OS command or |
|
|
|
| press the POWER/SLEEP switch. Take the modular server |
|
|
|
| out of the Module Enclosure, and install it again. Then, press |
|
|
|
| the POWER/SLEEP switch to turn on the modular server. |
|
|
| 4. | If the same error persists, contact your service representative. |
| 0BD4 | 2nd SMBus device Error | 1. | Take one of the following measures to reboot (reset) the |
|
| detected |
| modular server. |
| 0BD7 | 3rd SMBus device Error |
| * Issue an OS command. |
|
| detected |
| * Press Ctrl + Alt + Del. |
| 0BDA | 4th SMBus device Error |
| * Issue a command from Web browser of EXPRESSSCOPE |
|
| detected |
| Engine or NEC ESMPRO Manager. |
| 0BDD | 5th SMBus device Error | 2. | Take one of the following measures to power off the modular |
|
| detected |
| server and then on. |
| 0BE0 | 6th SMBus device Error |
| * Power off the modular server from OS, then press the |
|
| detected |
| POWER/SLEEP switch to power on. |
|
|
|
| * Press the POWER/SLEEP switch to power off the modular |
|
|
|
| server, then press it again to power on. |
|
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
|
| Engine or NEC ESMPRO Manager. |
|
|
| 3. | Power off the modular server by issuing an OS command or |
|
|
|
| press the POWER/SLEEP switch. Take the modular server |
|
|
|
| out of the Module Enclosure, and install it again. Then, press |
|
|
|
| the POWER/SLEEP switch to turn on the modular server. |
|
|
| 4. | If the same error persists, contact your service representative. |
| 8100 | Memory Error detected in | 1. | Run BIOS SETUP and select [Advanced] - [Memory |
|
| DIMM #1 |
| Configuration] - [Memory Retest] - [Yes] and reboot the |
| 8101 | Memory Error detected in |
| modular server. |
|
| DIMM #2 | 2. | DIMM may be faulty. Replace it with new one. |
|
|
| 3. | If the same error persists, contact your service representative. |
| 8150 | NVRAM Cleared By | Contact your service representative. | |
|
| Jumper |
|
|
| 8151 | Password Cleared By |
|
|
|
| Jumper |
|
|