Troubleshooting 7-11

 

 

 

 

 

 

 

On-screen error message

Recommended action

 

0BD1

1st SMBus device Error

1.

Take one of the following measures to reboot (reset) the

 

 

detected

 

modular server.

 

 

 

 

* Issue an OS command.

 

 

 

 

* Press Ctrl + Alt + Del.

 

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

 

Engine or NEC ESMPRO Manager.

 

 

 

2.

Take one of the following measures to power off the modular

 

 

 

 

server and then on.

 

 

 

 

* Power off the modular server from OS, then press the

 

 

 

 

POWER/SLEEP switch to power on.

 

 

 

 

* Press the POWER/SLEEP switch to power off the modular

 

 

 

 

server, then press it again to power on.

 

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

 

Engine or NEC ESMPRO Manager.

 

 

 

3.

Power off the modular server by issuing an OS command or

 

 

 

 

press the POWER/SLEEP switch. Take the modular server

 

 

 

 

out of the Module Enclosure, and install it again. Then, press

 

 

 

 

the POWER/SLEEP switch to turn on the modular server.

 

 

 

4.

If the same error persists, contact your service representative.

 

0BD4

2nd SMBus device Error

1.

Take one of the following measures to reboot (reset) the

 

 

detected

 

modular server.

 

0BD7

3rd SMBus device Error

 

* Issue an OS command.

 

 

detected

 

* Press Ctrl + Alt + Del.

 

0BDA

4th SMBus device Error

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

detected

 

Engine or NEC ESMPRO Manager.

 

0BDD

5th SMBus device Error

2.

Take one of the following measures to power off the modular

 

 

detected

 

server and then on.

 

0BE0

6th SMBus device Error

 

* Power off the modular server from OS, then press the

 

 

detected

 

POWER/SLEEP switch to power on.

 

 

 

 

* Press the POWER/SLEEP switch to power off the modular

 

 

 

 

server, then press it again to power on.

 

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

 

Engine or NEC ESMPRO Manager.

 

 

 

3.

Power off the modular server by issuing an OS command or

 

 

 

 

press the POWER/SLEEP switch. Take the modular server

 

 

 

 

out of the Module Enclosure, and install it again. Then, press

 

 

 

 

the POWER/SLEEP switch to turn on the modular server.

 

 

 

4.

If the same error persists, contact your service representative.

 

8100

Memory Error detected in

1.

Run BIOS SETUP and select [Advanced] - [Memory

 

 

DIMM #1

 

Configuration] - [Memory Retest] - [Yes] and reboot the

 

8101

Memory Error detected in

 

modular server.

 

 

DIMM #2

2.

DIMM may be faulty. Replace it with new one.

 

 

 

3.

If the same error persists, contact your service representative.

 

8150

NVRAM Cleared By

Contact your service representative.

 

 

Jumper

 

 

 

8151

Password Cleared By

 

 

 

 

Jumper