Troubleshooting 7-23

On-screen

Description

Action

message

 

 

BB Temp2 Alm 00

A low temperature

1. Check if fans in Module Enclosure work

 

warning was detected on

normally.

 

base board.

2. Refer to the User’s Guide of the Module

BB Temp2 Alm 07

A high temperature

Enclosure to make sure that the sufficient

 

warning was detected on

number of fans are installed in correct

 

base board.

locations.

BB Temp1 Alm 00

A low temperature

3. Check if the fans and modular servers are

 

warning was detected on

installed in correct locations.

 

base board.

4. Check if the ambient temperature of

BB Temp1 Alm 07

A high temperature

installation location satisfies the operation

 

warning was detected on

guarantee condition.

 

base board.

5. Take one of the following measures to

 

 

reboot (reset) the modular server.

 

 

* Issue an OS command.

 

 

* Press Ctrl + Alt + Del.

 

 

* Issue a command from Web browser of

 

 

EXPRESSSCOPE Engine or NEC

 

 

ESMPRO Manager.

 

 

6. Take one of the following measures to power

 

 

off the modular server and then on.

 

 

* Power off the modular server from OS,

 

 

then press the POWER/SLEEP switch to

 

 

power on.

 

 

* Press the POWER/SLEEP switch to power

 

 

off the modular server, then press it again

 

 

to power on.

 

 

* Issue a command from Web browser of

 

 

EXPRESSSCOPE Engine or NEC

 

 

ESMPRO Manager.

 

 

7. Power off the modular server by issuing an

 

 

OS command or press the POWER/SLEEP

 

 

switch. Take the modular server out of the

 

 

Module Enclosure, and install it again. Then,

 

 

press the POWER/SLEEP switch to turn on

 

 

the modular server.

 

 

8. If the same error persists, contact your

 

 

service representative.