Troubleshooting
Description | Action | ||
message | |||
|
| ||
Proc 1.05v Alm 02 | 1.05V voltage alarm | 1. Take one of the following measures to power | |
| (lower limit) occurred on | off the modular server and then on. | |
| processor. | * Power off the modular server from OS, | |
Proc 1.05v Alm 09 | 1.05V voltage alarm | then press the POWER/SLEEP switch to | |
| (upper limit) occurred on | power on. | |
| processor. | * Press the POWER/SLEEP switch to power | |
Proc Core Alm 02 | A core voltage alarm | off the modular server, then press it again | |
| (lower limit) was detected | to power on. | |
| in processor. | * Issue a command from Web browser of | |
Proc Core Alm 09 | A core voltage alarm | EXPRESSSCOPE Engine or NEC | |
| (upper limit) was detected | ESMPRO Manager. | |
| in processor. | 2. Power off the modular server by issuing an | |
|
| OS command or press the POWER/SLEEP | |
|
| switch. Take the modular server out of the | |
|
| Module Enclosure, and install it again. Then, | |
|
| press the POWER/SLEEP switch to turn on | |
|
| the modular server. | |
|
| 3. Check installation status of the heat sink of | |
|
| the modular server. | |
|
| 4. If the same error persists, contact your | |
|
| service representative. | |
Proc Missing | No processor is installed. | Contact your service representative. |